| | AF92V050U3 | AF92V075U3 | AF92V100U4 | AF92V125U5 |
Gas | Natural (Lp with Conversion Kit) | Natural (Lp with Conversion Kit) | Natural (Lp with Conversion Kit) | Natural (Lp with Conversion Kit) |
Input Rate (BTU per Hour) | 50,000/40,000 | 75,000/60,000 | 100,000/80,000 | 125,000/100,000 |
Heating Capacity (BTU per Hour) | 46,000 | 70,000 | 93,000 | 116,000 |
AFUE (Isolated Comb. System) | 92.1% | 92.1% | 92.1% | 92.1% |
Temperature Rise | 50°F | 55°F | 55°F | 55°F |
Volts/Phase/Hertz | 120/1/60 | 120/1/60 | 120/1/60 | 120/1/60 |
Static Pressure (Certified Max.) | Certified for 0.50" W.C. Maximum External Static | Certified for 0.50" W.C. Maximum External Static | Certified for 0.50" W.C. Maximum External Static | Certified for 0.50" W.C. Maximum External Static |
Blower Motor Horsepower | 1/2 | 1/2 | 3/4" | 1" |
Blower Wheel Size (Diameter x Width) | 10 x 6 | 10 x 6 | 12 x 9 | 12 x 12 |
Number of Heat Exchangers | 2 | 3 | 4 | 5 |
Flue and Air Inlet Pipe – (Diameter) (Schedule 40PVC, CPBC or ABS used on all) | 2" | 2" | 2" | 2" |
Limit Control, Snap Disk Style | 170°F | 170°F | 170°F | 170°F |
Gas Valve/Ignition Control | 2-Stage Gas Valve/Integrated Furnace Control with ECM Variable Speed Blower Motor | 2-Stage Gas Valve/Integrated Furnace Control with ECM Variable Speed Blower Motor | 2-Stage Gas Valve/Integrated Furnace Control with ECM Variable Speed Blower Motor | 2-Stage Gas Valve/Integrated Furnace Control with ECM Variable Speed Blower Motor |
Transformer | 40 Va. 115 VAC Primary, 24 VAC Secondary, Foot-Mounted | 40 Va. 115 VAC Primary, 24 VAC Secondary, Foot-Mounted | 40 Va. 115 VAC Primary, 24 VAC Secondary, Foot-Mounted | 40 Va. 115 VAC Primary, 24 VAC Secondary, Foot-Mounted |
Maximum Outlet Temperature | 180°F | 180°F | 180°F | 180°F |
Shipping Weights | 152 | 158 | 187 | 217 |